Heat shrinkable anti-tracking tubing designed for high-performance electrical insulation in outdoor, polluted, and high-stress environments where resistance to surface tracking, erosion, and weathering is critical.

Engineered for Outdoor and High-Stress Insulation Demands

Anti-tracking tubing is formulated specifically for medium- and high-voltage insulation applications where standard polyolefin tubing is insufficient. In outdoor and polluted environments, moisture and contamination on cable insulation surfaces can form conductive paths — leading to surface tracking, erosion, and eventual insulation failure. Anti-tracking tubing resists this degradation mechanism through a specialised compound that suppresses carbonised tracking paths and withstands erosion under sustained leakage current.

Suitable for MV cable core reconstruction, sheath repair, termination insulation, and outdoor installations subject to coastal, industrial, or high-pollution exposure.

Quick Reference
  • Material Crosslinked Polyolefin (AT grade)
  • Shrink ratio 3:1 minimum
  • Tracking resistance Yes — IEC 60587
  • UV / weather resistance Yes
  • Flame retardant Yes — IEC 60332-1
  • Halogen-free Yes
  • Operating temperature –55°C to +110°C

Why Anti-Tracking Tubing Is Specified

Purpose-formulated for environments where conventional tubing fails under sustained electrical stress, pollution, and weathering.

High-Voltage Insulation Performance

Formulated for MV and HV insulation applications where dielectric performance must be maintained under sustained electrical stress, elevated leakage current, and contaminated surface conditions.

Anti-Tracking and Erosion Resistance

The AT compound suppresses the formation of carbonised conductive tracks on the tubing surface — preventing progressive erosion and insulation failure in polluted or moisture-exposed installations.

UV and Weather Durability

UV-stabilised compound maintains mechanical and electrical properties after prolonged outdoor exposure — suitable for above-ground cable runs, overhead structures, and exposed substation installations.

Wide Accommodation with 3:1 Shrink Ratio

The 3:1 shrink ratio allows a single tubing size to cover a broad range of cable and insulation diameters — simplifying procurement and reducing the number of stocked sizes required per project.

Flame-Retardant, Halogen-Free Construction

Compliant with IEC 60332-1 for flame retardance and formulated without halogens — meeting safety and environmental requirements for enclosed and confined installation environments.

Reliable Field Installation

Applied using a standard hot air gun or controlled-flame torch — no specialist tooling required. Consistent recovery is achievable by trained technicians in field or workshop conditions.

Material & Performance Data

Reference data for engineering and procurement. Contact our technical team for full test reports or project-specific qualification data.

Base material Irradiation-crosslinked polyolefin — anti-tracking grade
Standard colour Black
Shrink ratio 3:1 minimum (recovered wall : supplied diameter)
Tracking resistance Yes — tested to IEC 60587 (electrical tracking and erosion)
UV / weather resistance Yes — UV-stabilised, suitable for prolonged outdoor exposure
Flame retardant Yes — compliant with IEC 60332-1
Halogen-free Yes
Operating temperature –55°C to +110°C (continuous service)
Installation method Hot air gun or controlled-flame torch — standard heat shrink application
Chemical resistance Resistant to oils, fuels, mild acids, and alkalis in recovered state
Shelf life 10 years from manufacture date when stored per IEC 60684 storage guidelines
Applicable standards IEC 60684 (heat-shrinkable tubing), IEC 60587 (tracking resistance), IEC 60332-1 (flame retardance)

Where Anti-Tracking Tubing Is Used

Specified wherever surface tracking, pollution, and environmental degradation are design risks in medium- and high-voltage installations.

01

MV/HV Cable Terminations

Applied over the insulation screen cutback and cable insulation at medium- and high-voltage terminations to maintain dielectric integrity and prevent surface tracking at the insulation interface.

02

Pollution-Prone Substations

Used in coastal, industrial, and heavily contaminated substation environments where conventional tubing is susceptible to leakage current, tracking, and progressive insulation degradation.

03

Cable Core Reconstruction

Applied over stripped MV cable cores during jointing and termination to re-establish the insulation layer with anti-tracking performance equivalent to the original cable design.

04

Sheath Repair

Used to repair and reinstate damaged cable sheaths on MV outdoor cables — restoring mechanical protection, weather resistance, and tracking resistance without cable replacement.

05

Renewable Energy Systems

Specified on solar and wind energy cable systems where outdoor UV exposure, temperature cycling, and elevated leakage current demand long-term insulation stability in unshielded environments.

06

Utility and Industrial Networks

Applied across utility distribution infrastructure and industrial electrical installations where outdoor cable runs require sustained insulation performance in challenging service environments.

How to Select the Right Anti-Tracking Tubing

Six criteria determine the correct size and specification. Work through each before ordering to ensure the tubing performs correctly in the intended service environment.

  1. 01

    Voltage Class

    Confirm the system voltage and the voltage class of the cable accessory being installed. Anti-tracking tubing is specified for MV and HV applications — ensure the selected product is rated for the operating voltage of the installation.

  2. 02

    Cable Size and Insulation Type

    Measure the outer diameter of the cable insulation at the point of application. For terminations, this is typically the stripped insulation diameter. Confirm the cable insulation material to ensure chemical compatibility with the tubing compound in recovered contact.

  3. 03

    Required Tubing Length

    Determine the length of tubing required based on the coverage area specified in the accessory installation instruction or engineering drawing. Allow for the shrinkage in length that occurs during heat application — typically 5–10% axial shrinkage depending on tubing size and recovery method.

  4. 04

    Indoor or Outdoor Exposure

    Anti-tracking tubing is designed for outdoor and high-stress environments. Confirm whether the installation is fully outdoor, partially sheltered, or indoor with elevated pollution — this affects the tracking resistance class required and any additional environmental sealing specification.

  5. 05

    Pollution Severity and Service Environment

    Assess the pollution severity at the installation site — coastal salt, industrial particulate, chemical vapour, and heavy rain exposure each affect the rate of leakage current and tracking risk. Higher pollution environments may require a tracking resistance class above the minimum — confirm with our technical team for site-specific guidance.

  6. 06

    Quantity and Project Location

    Confirm total quantities by tubing size, along with the project location and required delivery schedule. Western Cablex can support project-specific supply, phased delivery, and technical documentation for utility and EPC procurement requirements.

If the application involves non-standard cable dimensions, elevated voltage, or severe pollution conditions, contact our technical team before finalising the specification.

Common Technical Questions

Need Help Selecting the Right Anti-Tracking Tubing?

Speak with our technical team for sizing, application guidance, and product recommendations.