Tubing

Insulation Tubing

Heat shrinkable insulation tubing designed to provide reliable electrical insulation, protection, and identification for wires, cables, and components across low-voltage and general industrial applications.

General-Purpose Insulation for Wiring and Cable Systems

Insulation tubing provides a practical and reliable heat-shrinkable covering for electrical conductors, components, and cable assemblies in low-voltage and general industrial applications. When heat is applied, the tubing recovers uniformly over the substrate — forming a consistent insulation layer that protects against electrical contact, abrasion, moisture ingress, and mechanical damage without the inconsistency of tape wrapping or the bulk of moulded components.

The 2:1 shrink ratio covers a broad range of wire and cable diameters within a standard size range, making it suitable for panel wiring, wire harness assembly, terminal insulation, and cable identification across industrial, infrastructure, and electrical installation applications.

Quick Reference
  • Material Crosslinked Polyolefin
  • Shrink ratio 2:1 minimum
  • Standard colours Black, Red, Blue, Yellow, Green, White
  • Flame retardant Yes — IEC 60332-1
  • Halogen-free Yes
  • Operating temperature –55°C to +125°C

Why Insulation Tubing Is Specified

A versatile, field-proven insulation solution for wire and cable protection across general industrial and electrical installation applications.

Reliable Electrical Insulation

Provides consistent dielectric protection over conductors, terminals, and exposed cable sections — eliminating accidental electrical contact and meeting insulation requirements for LV wiring and panel assembly applications.

Abrasion and Mechanical Protection

The recovered tubing wall protects wire and cable surfaces against abrasion, chafing, and physical damage — particularly at conduit entries, cable routing transition points, and areas of sustained mechanical contact.

Moisture Resistance

Recovered tubing forms a continuous, close-fitting barrier over the conductor surface — providing resistance to moisture, humidity, and incidental fluid exposure in panel, industrial, and outdoor installation environments.

Flexible and Conformable Fit

Recovers tightly over irregular profiles, stepped conductors, and terminal geometries — conforming to the substrate surface without lifting, wrinkling, or leaving voids. Remains flexible after recovery, maintaining fit over service life.

Colour Coding Capability

Available in a full range of standard colours to support circuit identification, phase marking, and wire harness colour-coding — eliminating the need for separate adhesive labels or markers on insulated conductors.

Easy Installation

Applied using a standard hot air gun with no specialist tooling or equipment calibration. Fast recovery reduces installation time in panel assembly and harness manufacturing environments where tubing is applied at volume.

Material & Performance Data

Reference data for engineering and procurement. Contact our technical team for full test reports or project-specific qualification data.

Base material Irradiation-crosslinked polyolefin
Standard colours Black, Red, Blue, Yellow, Green, White — additional colours on request
Shrink ratio 2:1 minimum
Operating temperature –55°C to +125°C (continuous service)
Dielectric strength Suitable for LV insulation applications — refer to product datasheet for voltage withstand values by size
Flame retardant Yes — compliant with IEC 60332-1
Halogen-free Yes
UV resistance UV-stabilised — suitable for outdoor and exposed installations
Chemical resistance Resistant to oils, fuels, mild acids, and alkalis in recovered state
Installation method Hot air gun — 2:1 shrink ratio achieved at standard heat shrink temperatures
Shelf life 10 years from manufacture date when stored per IEC 60684 storage guidelines
Applicable standards IEC 60684 (heat-shrinkable tubing), IEC 60332-1 (flame retardance)

Where Insulation Tubing Is Used

A standard component across electrical installation, panel assembly, and industrial wiring wherever reliable conductor insulation and identification are required.

01

Electrical Wiring Insulation

Applied over bare conductors, stripped cable ends, and splice points to restore or supplement insulation in LV wiring systems — providing a consistent, field-applied insulation layer without tape wrapping.

02

Wire Harnessing

Used in wire harness assembly to insulate individual conductors, bundle entry points, and branch-off locations — providing colour-coded insulation that integrates with harness design specifications and identification requirements.

03

Panel and Switchgear Wiring

Applied in panel build and switchgear assembly environments to insulate terminal connections, bus links, and wiring runs where exposed conductors require consistent insulation and phase colour identification.

04

Cable Identification

Colour-coded tubing applied at cable ends and termination points to provide durable circuit identification — replacing adhesive labels and marker sleeves with a heat-shrunk insulation-grade identification covering.

05

Connector and Terminal Insulation

Applied over crimped terminals, connector pins, and cable lugs to insulate exposed metallic contact points and prevent accidental electrical contact in panel, equipment, and field installation environments.

06

Industrial Electrical Systems

Used across industrial facilities, manufacturing environments, and infrastructure installations wherever conductor insulation, mechanical protection, and colour identification are standard wiring practice requirements.

How to Select the Right Insulation Tubing

Six criteria determine the correct size, colour, and specification. Work through each before ordering to ensure the tubing is correctly matched to the conductor dimensions and application requirements.

  1. 01

    Wire or Cable Outer Diameter

    Measure the outer diameter of the wire, cable, or component at the point where the tubing will be applied. For the tubing to recover correctly, the substrate diameter must fall within the tubing's recovery range — between the recovered inner diameter and the supplied inner diameter. For a 2:1 product, select the size whose recovered diameter is equal to or slightly smaller than the substrate outer diameter.

  2. 02

    Shrink Ratio

    Standard insulation tubing has a 2:1 shrink ratio — the tubing recovers to half its supplied inner diameter. This is suitable for most wiring insulation, terminal covering, and cable identification applications. Where a wider range of substrate diameters must be covered by a single tubing size, consider medium wall tubing at 3:1 shrink ratio as an alternative.

  3. 03

    Installation Environment

    Confirm whether the application is indoors, outdoors, or in an environment with elevated temperature, moisture, or chemical exposure. Standard insulation tubing is UV-stabilised and suitable for outdoor use. For applications requiring moisture sealing at the tubing ends, consider medium wall adhesive-lined tubing as an alternative.

  4. 04

    Colour Requirement

    Select the colour based on the circuit identification, phase marking, or harness colour-coding requirement of the installation. Standard colours — black, red, blue, yellow, green, and white — are held in stock. Additional colours may be available on request. Confirm colour availability before placing an order for non-standard requirements.

  5. 05

    Voltage Level

    Insulation tubing is designed for LV and general-purpose insulation applications. Confirm that the voltage withstand value for the selected tubing size is adequate for the system voltage of the application. For MV insulation requirements, medium wall or anti-tracking tubing should be specified instead.

  6. 06

    Required Length

    Determine the total tubing length required per conductor or application point. Allow for axial shrinkage during heat application — typically 5–10% depending on tubing size and recovery conditions. For harness or panel assembly applications at volume, insulation tubing is available in standard reel or cut-length supply formats.

If the application involves elevated voltage, aggressive chemical exposure, or non-standard substrate dimensions, contact our technical team before finalising the specification.

Common Technical Questions