Anti-Tracking Mastic

Anti-tracking mastic designed to provide surface insulation and resistance to electrical tracking and erosion at outdoor medium-voltage cable terminations — maintaining dielectric surface integrity under combined electrical stress, moisture, ultraviolet exposure, and environmental contamination.

Surface Tracking Resistance for Outdoor medium-voltage Terminations

Anti-Tracking Mastic is applied to exposed insulation surfaces on outdoor medium-voltage cable terminations to resist surface tracking — the progressive formation of carbonised conductive paths from contamination and electrical stress that can lead to termination flashover over time.

Anti-Tracking Mastic is hand-wrapped at exposed interfaces, bushing transitions, and lug connections — conforming to irregular profiles and self-amalgamating under hand pressure with no heat required. Suitable for both new installations and retrofit during planned maintenance.

Quick Reference
  • Material Anti-tracking elastomer mastic
  • Colour Red (standard)
  • Voltage medium-voltage outdoor applications
  • Application Hand-wrapped — no heat required
  • Form Roll — self-amalgamating strip
  • ultraviolet rated Yes
  • Function Surface tracking resistance

Why Anti-Tracking Mastic Is Specified

Directly addresses the surface tracking failure mechanism at outdoor medium-voltage terminations — applied by hand with no heat equipment required.

Anti-Tracking Performance

Anti-tracking compound formulation resists surface carbonisation under combined electrical stress and contamination — suppressing the leakage current paths that initiate and propagate tracking on outdoor termination surfaces over time.

ultraviolet and Weather Resistance

ultraviolet-stabilised compound maintains anti-tracking properties and surface integrity through prolonged direct outdoor exposure — including high ultraviolet index tropical and coastal environments where standard polymer surfaces degrade more rapidly.

Pollution and Contamination Resistance

Resistant to salt deposits, industrial particulates, and biological surface contamination — the primary pollution types that create conductive surface films on outdoor terminations in coastal, industrial, and high-humidity environments.

Surface Insulation Protection

Forms a continuous, conforming insulating layer over exposed termination interfaces — protecting cable insulation surfaces, lug connections, and bushing transitions from surface degradation and environmental attack throughout outdoor service life.

Durable Long-Term Performance

Maintains anti-tracking properties and adhesion across the operating temperature range and thermal cycling conditions of outdoor medium-voltage service — providing reliable surface protection throughout the service life of the cable termination without periodic reapplication.

Simple Hand Application

Self-amalgamating strip wraps and melds under hand pressure — no heat gun, resin mixing, or specialist tooling required. Suitable for both initial termination assembly on new installations and retrofit application during planned maintenance on existing terminations.

Material & Performance Data

Reference data for engineering and procurement. Contact our technical team for test data or project-specific qualification requirements.

Base material Anti-tracking elastomer mastic — insulating grade with anti-tracking compound
Colour Red (standard)
Form factor Roll — self-amalgamating strip; conforms under hand pressure without heat
Voltage application Medium-voltage outdoor terminations — up to 33 kV system voltage
Electrical function Surface insulation with anti-tracking compound — resists carbonised surface path formation
Tracking resistance Anti-tracking grade — consistent with IEC 60587 requirements
ultraviolet resistance Yes — ultraviolet-stabilised, rated for continuous direct outdoor exposure
Application method Hand-applied — wrap and mould; no heat source required
Operating temperature –55°C to +90°C (continuous service)
Compatible systems Outdoor medium-voltage heat shrink terminations, polymeric outdoor termination assemblies

Where Anti-Tracking Mastic Is Used

Applied at exposed insulation interfaces on outdoor medium-voltage terminations wherever surface tracking resistance is required under pollution and electrical stress conditions.

01

Outdoor medium-voltage Cable Terminations

Primary application — applied over exposed insulation surfaces and interfaces on 11 kV and 33 kV outdoor cable terminations to provide anti-tracking protection at the termination body and cable-to-lug transition zones.

02

Exposed Bushing and Lug Interfaces

Applied at the cable-to-bushing and cable-to-lug interfaces where the insulation surface is exposed to weather and contamination — sealing irregular profiles and providing anti-tracking protection at the most contamination-prone areas of the termination.

03

Coastal and Marine Installations

Outdoor terminations in coastal and marine environments where salt-laden air creates high-conductivity surface contamination — Anti-Tracking Mastic provides the anti-tracking surface layer required to maintain termination integrity under Class III and IV pollution severity conditions.

04

Industrial and Polluted Sites

Outdoor medium-voltage terminations in industrial facilities where airborne contamination from manufacturing processes, chemical plants, or heavy transport creates elevated pollution loading on termination surfaces — requiring anti-tracking protection beyond that provided by the base termination material.

05

Distribution Substation Terminations

Outdoor cable entries at distribution substations and ring main unit installations in pollution-prone locations — where long maintenance intervals and high asset reliability requirements make anti-tracking surface protection a standard specification.

06

Overhead Line Transition Terminations

Underground-to-overhead cable transition terminations at pole and tower bases — continuously exposed outdoor terminations where combined weather, ultraviolet, and pollution loading makes anti-tracking surface protection necessary for long-term reliability.

When and How to Use Anti-Tracking Mastic

Anti-Tracking Mastic is applied at specific exposed surfaces on outdoor medium-voltage terminations. Confirm the application requirement against each criterion before specifying.

  1. 01

    Outdoor Installation Requirement

    Anti-Tracking Mastic is specified for outdoor medium-voltage terminations where the termination body or cable interfaces are exposed to weather, ultraviolet radiation, and environmental contamination. For indoor medium-voltage terminations in clean, enclosed environments, Anti-Tracking Mastic is generally not required — however, for indoor installations in contaminated or humid industrial environments where surface tracking risk exists, contact our technical team for confirmation of whether Anti-Tracking Mastic is appropriate for the specific installation conditions.

  2. 02

    Pollution Severity of the Site

    Assess the pollution severity class of the installation site using IEC 60815 — ranging from Class I (very light) to Class IV (very heavy). Anti-Tracking Mastic is particularly relevant for Class II and above, where surface contamination is sufficient to create leakage current paths. Coastal, industrial, and high-humidity sites typically fall into Class III or IV. For Class I sites with minimal pollution, confirm whether Anti-Tracking Mastic is needed based on the specific environmental conditions at the termination location.

  3. 03

    Anti-Tracking Mastic vs Stress Control Mastic vs Black Mastic — Correct Formulation

    Anti-Tracking Mastic is an insulating mastic with anti-tracking compound — for surface protection on exposed outdoor termination bodies. It does not provide electrical stress grading and must not be substituted for Stress Control Mastic at insulation screen cut-backs. Similarly, Black Mastic does not contain anti-tracking compound and must not be used in place of Anti-Tracking Mastic for outdoor surface protection. Apply each formulation only at the locations specified in the joint or termination kit installation instructions.

  4. 04

    Application Location on the Termination

    Anti-Tracking Mastic is applied to exposed insulation and interface surfaces on the termination — not over heat shrink tubes that are already recovered and sealed. Typical application points include: exposed cable insulation above the heat shrink termination body, the cable-to-lug or cable-to-bushing transition where insulation is exposed at the connection interface, and any area where the termination assembly leaves insulation material exposed to direct outdoor conditions. Follow the kit installation instructions for the specific application sequence and coverage area.

For medium-voltage terminations in very heavily polluted environments (IEC 60815 Class IV), consider Anti-Tracking Mastic in combination with Creepage Extension Sheds to provide both surface protection and extended creepage distance at the termination. Contact our technical team for a combined specification recommendation.

Common Technical Questions

Need Help Specifying the Right Mastic for Your Application?

Speak with our technical team for formulation guidance, system compatibility confirmation, and supply enquiries.